REMEDY:
• Adjust bypass damper to fully open position.
• Ensure the bypass tube is fully stretched out tight.
• Furnace filter is dirty and needs replacement.
• Bypass tube and humidifier not installed parallel, use hard
ducting – use hard ducting for any elbows – take the most
direct route when ducting.
• The bypass tube or humidifier is installed in front of air-
conditioning coils or is blocked in some other way – move to
another location and ensure maximum air flow.
• The fan delay on your furnace is not set properly and the
furnace fan is shutting off too early when the air is still hot. You
should discuss with a HVAC professional to have your
furnace’s fan cycle adjusted so you are maximizing the heat
delivered to your home. If the furnace is not adjusted you will
have to consider the use of a flow through pressure switch
(through our parts and service line) or bypass the humidifiers
control and have the unit hardwired to your furnace by an
electrician or HVAC professional.
Your furnace is located in an enclosed space like a closet,
and as a result the temperature in that space is very hot , this
is not a good condition. Proper ventilation is necessary for
your furnace to operate properly you should consult a
HVAC professional. If this is the case you will have to
consider the use of a flow through pressure switch (through
our parts and service line) or bypass the humidifiers control
and have the unit hardwired to your furnace by an
electrician or HVAC professional.
• Your furnace is not operating properly and running too hot –
consult a HVAC professional.
PROBLEM: THE HUMIDISTAT READING DOES NOT
SEEM TO MATCH THE HUMIDITY LEVEL IN THE HOME;
IT IS HIGHER OR LOWER
POSSIBLE CAUSE: Dirty humidistat sensor.
REMEDY: Carefully clean the humidity sensor located at the back
of the humidistat. You will have to remove the humidistat from the
duct and gently blow on the sensor located at the back of the unit.
POSSIBLE CAUSE: The humidistat is located near a fresh air intake
REMEDY: Fresh outdoor air is sometimes introduced to the home
through the duct work, if you have located the humidistat near
one of these intakes the humidistat will be giving a false reading
try to relocate the humidistat to another part of the return duct.
PROBLEM: NO WATER GETTING TO THE EVAPORATOR PAD
POSSIBLE CAUSE: Humidistat is not turned up.
REMEDY: Turn up the humidistat.
POSSIBLE CAUSE: The unit is not plugged in.
REMEDY: Plug in the unit.
POSSIBLE CAUSE: The furnace is not in heating mode.
REMEDY: The furnace must be blowing hot air for this
unit to work.
POSSIBLE CAUSE: Water supply is not turned on.
REMEDY: Check to make sure water is flowing from the
piercing valve.
POSSIBLE CAUSE: Water is blocked at either the water inlet filter
or at the orifice fitting.
REMEDY: Check both components to ensure no blockage exists.
POSSIBLE CAUSE: Solenoid valve is not working.
REMEDY: Replace the solenoid valve.
PROBLEM: THERE IS TOO MUCH WATER
GOING DOWN THE DRAIN
POSSIBLE CAUSE: The unit is installed improperly and is not
performing efficiently.
REMEDY: Check your installation in the appropriate section in
the instructions and make any necessary adjustments.
POSSIBLE CAUSE: The unit is working properly and the
furnace is supplying the proper conditions – just not happy
with the water usage.
REMEDY: Flow thru humidifiers will use water. This unit has an
orifice fitting which meters the amount of water used. A total of
approx 56 US gallons will be used in 24 hours of operation. – 24
hours of operation could take as much as 3 days to complete
depending on how often your furnace cycles on. When
compared to the average shower which uses approx. 5 gallons
per minute. The amount of water used to humidifier your home
is not that much.
PROBLEM: TOO MUCH HUMIDITY IN THE HOME
POSSIBLE CAUSE: Humidistat set too high.
REMEDY: Turn humidistat down.
POSSIBLE CAUSE: Humidistat in Automatic mode and outdoor
air sensor is sensing a source of heat.
REMEDY: The outdoor air sensor will adjust the humidity level
based on outdoor air temperatures, if it is sensing air from a dryer
vent or exhaust fan vent then it will provide false readings. –
move sensor location.